Transducer,0/50,Wet,LCD
Pressure Transducers
Gallery
Attributes
| Brand name, Manufacturer name, Manufacturer, Brand, Label, Man, Publisher, Studio | Veris |
|---|---|
| CategoryId, CategoryIdL3 | 4842 |
| CategoryIdL1 | 24 |
| CategoryIdL2 | 4533 |
| CategoryL1 | Test Instruments & Gauges |
| CategoryL2 | Pressure & Vacuum Measuring |
| CategoryL3 | Pressure Transducers |
| DimensionUnit | inch |
| GraingerSku | 387M19 |
| Extra Product Name | Transducer,0/50,Wet,LCD |
| UPC | None |
| UnitOfMeasure | EA |
| Weight | 2.2 1.9 1.90 |
| WeightUnit | lbs |
| cali_prop65_orglabel, cali_prop65_whtlabel, AdultProduct, Autographed, Memorabilia, TradeInEligible | False |
| countryOfOrigin | US |
| extendedLead | 20 |
| extendedQty | -2 |
| height | 3 |
| jsonUrlData | 924526ffbdad25e5923b |
| length | 7 |
| moq, multiple, tierMinQty1, Case, NumberOfItems, Number_of_items | 1 |
| MPN, Part Number, Model, Keyword, ModelNumber, Model_number, Mpns, PartNumber, Part_number, StrippedMpns | PWLX03S |
| qtyInStock | 0 |
| qtyInStockOverride | Drop Ship |
| SKU | G9546490 |
| tierPrice1 | 582.86 |
| url | https://www.zoro.com/veris-transducer-050-wet-lcd-pwlx03s/i/G9546490/ |
| width | 6 |
| Product Group, ProductGroup, WebsiteDisplayGroupName | BISS Basic |
| Item | Transducer,0/50#,Wet,LCD |
| ASIN, Asin | B008HOYL88 |
| Amount | 0.00 |
| Binding | Misc. |
| Bullet_point | APPLICATIONS Monitoring and controlling pump differential pressureChiller/boiler differential pressure dropCW/HW system differential pressureFeaturesThe jumper-selectable output switch for normal (4-20mAor reverse (20-4mAoperation provides application flexibility Rugged, die-cast enclosure provides NEMA 4 sealing Exceptional accuracy and stability Dual sensor design for improved overpressure toleranceJumper-controlled electronic surge dampening for high stabilityPushbutton zero calibration no trim pots to adjustLowest total installed costJumper-selectable port swap feature eliminates costly replumbing when the high and low ports are improperly plumbed Easy to use and designed to provide exceptional installation savings, the PWL Series is ideal for measuring pressure across pumps, filters, heat exchangers, compressors, and other non-corrosive wet media applications The LCD display allows easy visibility The PWL Series wet/wet pressure transducers incorporate microprocessor profiled sensors for exceptional accuracy and reliability |
| Cat | Industrial & Scientific |
| CatId | 16310091 |
| CatTree | 16310091 16310161 306506011 306767011 306821011 |
| ClassificationId | 306827011 |
| Currency, CurrencyCode | USD |
| DisplayName | Voltage |
| Feature | The PWL Series wet/wet pressure transducers incorporate microprocessor profiled sensors for exceptional accuracy and reliability |
| Height, Width | 1920 2560 375 500 56 75 |
| IsBrandQuery | True |
| ItemClassification | BASE_PRODUCT |
| ItemName, Item_name | Veris,Pressure,Wet,NEMA 4,LCD,0-50PSID, PWLX03S |
| Item_type_keyword | voltage-transducers |
| Item_weight | 1.9 |
| Link | https://m.media-amazon.com/images/I/31--fjtg6zL._SL75_.jpg https://m.media-amazon.com/images/I/31--fjtg6zL.jpg https://m.media-amazon.com/images/I/31MzQmFJEYL._SL75_.jpg https://m.media-amazon.com/images/I/31MzQmFJEYL.jpg https://m.media-amazon.com/images/I/41+NINPOGpL._SL75_.jpg https://m.media-amazon.com/images/I/41+NINPOGpL.jpg https://m.media-amazon.com/images/I/41B8jQnuiNL._SL75_.jpg https://m.media-amazon.com/images/I/41B8jQnuiNL.jpg https://m.media-amazon.com/images/I/41op12FKBwL._SL75_.jpg https://m.media-amazon.com/images/I/41op12FKBwL.jpg https://m.media-amazon.com/images/I/8184MZnS3AL.jpg https://m.media-amazon.com/images/I/81ApXIY-IxL.jpg https://m.media-amazon.com/images/I/81OYiDm-QaL.jpg https://m.media-amazon.com/images/I/81UoZ5Pvg0L.jpg https://m.media-amazon.com/images/I/81oPopUVUfL.jpg https://www.amazon.com/gp/bestsellers/industrial https://www.amazon.com/gp/bestsellers/industrial/306827011 |
| List_price | 0.0 |
| ProductCategoryId | 306827011 biss_display_on_website |
| ProductType, ProductTypeName | ELECTRONIC_COMPONENT |
| Product_description | Input Power 12 to 30VDC/24VAC nominalMaximum Current Draw DC: 125mA; AC: 280mAOutput 3-wire transmitter; user selectable 4-20mA (clipped and capped)/0-5V/0-10V Accuracy @ 25°C* Range A B C: ±1% F.S.; Range D: ±2% F.S.**Surge Damping Electronic; 5-second averagingTest Mode Overrides output to full-scale (20mA 5V 10V)Pressure Ranges (Selectable) 0-10/20/50/100psid (0-0.34/0.69/1.72/3.45 bar)Product Operating Environment -10° to 55°C (-140° to 130°F); 0 to 90%RH non-condensingLong Term Stability ±0.25% per yearZero Adjust Pushbutton auto-zero and digital input (2-pos terminal block)Status Indication Dual-color LED: Green = Normal Green Blinking = Low > High Red = Overrange Red Blinking = OverpressureHousing Material White powder-coated aluminumSensor:Media Compatibility Media compatible with 17-4 PH stainless steelProof Pressure Max. 2x F.S. rangeBurst Pressure Max. 5x F.S. rangeTemperature Compensated Range 0° to 50°C (32° to 122°F); TC Zero Media Temperature Limits -20° to 85°C (-4° to 185°F); 0 to 90% RH non-condensingFittings 1/8" NPT female thread 17-4 PH stainless Minimum input voltage for 4-20mA operation: 250 ohm loop (1-5V) = 12 VDC; 500 ohm loop (2-10V) = 15 VDC; Minimum input voltage for volt operation: 0-5VDC output = 12 VDC; 0-10VDC output = 15 VDC. *Accuracy combines linearity hysteresis and repeatability.**FS is defined as full span of selected range in bi-directional mode. |
| Product_site_launch_date | 2012-07-05T09:41:29.258Z |
| Rank | 1 1149118 1152929 12 364621 41 446718 49 6 64 70225 857098 865596 |
| Sku | LNT2H822MSEJ VERIS PWLX03S |
| Style | #N/A |
| Title | Industrial & Scientific Veris,Pressure,Wet,NEMA 4,LCD,0-50PSID, PWLX03S Voltage Transducers |
| URL | http://ecx.images-amazon.com/images/I/41jLnKF96eL._SL75_.jpg https://m.media-amazon.com/images/I/31--fjtg6zL._SL75_.jpg https://m.media-amazon.com/images/I/41jLnKF96eL._SL75_.jpg |
| Unit | pounds |
| Units | pixels pounds |
| Variant | MAIN PT01 PT02 PT03 PT04 |
| WebsiteDisplayGroup | biss_basic_display_on_website biss_display_on_website |
Distributor offers
| Seller | SKU | MOQ | In stock | Multiple | Prices |
|---|---|---|---|---|---|
| G9546490 | 1 | 1 | 1 @ $582.86 | ||
![]() Voomi Supply | PWLX03S | 1 | -2 | 1 | 1 @ $714.12 |
![]() midwestapplianceparts.com | PWLX03S-VE-P | 1 | -2 | 1 | 1 @ $662.29 |
| PWLX03S | 1 | 3 | 1 | 1 @ $741.31 | |
| hvacdiscountstore.com | VER--PWLX03S | 1 | 7 | 1 | 1 @ $726.20 |
![]() Galco | PWLX03S-VEIN | 1 | 1 | 1 @ $646.34 | |
| PWLX03S | 1 | 7 | 1 | 1 @ $691.08 | |
![]() blackhawksupply.com | PWLX03S | 1 | EXTENDED LEAD TIME; 3-4 WEEKS | 1 | 1 @ $438.46 |
| alliedcontrols.com | PWLX03S | 1 | Factory Stock | 1 | 1 @ $408.65 |
| PWLX03S | 1 | -2 | 1 | 1 @ $386.98 | |
| PWLX03S | 1 | 1 | 1 @ $835.06 | ||
| globaltestsupply.com | PWLX03S | 1 | 2 to 3 Weeks | 1 |
Related on Amazon
As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Veris,Pressure,Wet,NEMA 4,LCD,0-50PSID, PWLX03S
Brand: Veris
Input Power 12 to 30VDC/24VAC nominalMaximum Current Draw DC: 125mA; AC: 280mAOutput 3-wire transmitter; user selectable 4-20mA (clipped and capped)/0-5V/0-10V Accuracy @ 25°C* Range A B C: ±1% F.S.; Range D: ±2% F.S.**Surge Damping Electronic; 5-second averagingTest Mode Overrides output to full-scale (20mA 5V 10V)Pressure Ranges (Selectable) 0-10/20/50/100psid (0-0.34/0.69/1.72/3.45 bar)Product Operating Environment -10° to 55°C (-140° to 130°F); 0 to 90%RH non-condensingLong Term Stability ±0.25% per yearZero Adjust Pushbutton auto-zero and digital input (2-pos terminal block)Status Indication Dual-color LED: Green = Normal Green Blinking = Low > High Red = Overrange Red Blinking = OverpressureHousing Material White powder-coated aluminumSensor:Media Compatibility Media compatible with 17-4 PH stainless steelProof Pressure Max. 2x F.S. rangeBurst Pressure Max. 5x F.S. rangeTemperature Compensated Range 0° to 50°C (32° to 122°F); TC Zero Media Temperature Limits -20° to 85°C (-4° to 185°F); 0 to 90% RH non-condensingFittings 1/8" NPT female thread 17-4 PH stainless Minimum input voltage for 4-20mA operation: 250 ohm loop (1-5V) = 12 VDC; 500 ohm loop (2-10V) = 15 VDC; Minimum input voltage for volt operation: 0-5VDC output = 12 VDC; 0-10VDC output = 15 VDC. *Accuracy combines linearity hysteresis and repeatability.**FS is defined as full span of selected range in bi-directional mode.
Details
- The PWL Series wet/wet pressure transducers incorporate microprocessor profiled sensors for exceptional accuracy and reliability
- Easy to use and designed to provide exceptional installation savings, the PWL Series is ideal for measuring pressure across pumps, filters, heat exchangers, compressors, and other non-corrosive wet media applications
- The LCD display allows easy visibility
- APPLICATIONS Monitoring and controlling pump differential pressureChiller/boiler differential pressure dropCW/HW system differential pressureFeaturesThe jumper-selectable output switch for normal (4-20mAor reverse (20-4mAoperation provides application flexibility Rugged, die-cast enclosure provides NEMA 4 sealing Exceptional accuracy and stability
- Dual sensor design for improved overpressure toleranceJumper-controlled electronic surge dampening for high stabilityPushbutton zero calibration no trim pots to adjustLowest total installed costJumper-selectable port swap feature eliminates costly replumbing when the high and low ports are improperly plumbed
Listing
| Product group | BISS Basic |
|---|---|
| Product type | ELECTRONIC_COMPONENT |
| Model | PWLX03S |
| Part number | PWLX03S |
| Items per pack | 1 |
| Label | Veris |
| Manufacturer | Veris |
Catalog
| Feature | The PWL Series wet/wet pressure transducers incorporate microprocessor profiled sensors for exceptional accuracy and reliability |
|---|---|
| Category | Industrial & Scientific |
| MPN | PWLX03S |
| Product group | BISS Basic |
| Product type | ELECTRONIC_COMPONENT |
| Manufacturer | Veris |