As an Amazon Associate, we earn from qualifying purchases.

PWLN04S Veris Industries 3wire DiffPressureXdcr 0-100# | Midwest Appliance Parts

Authentic OEM part PWLN04S by Veris. We provide free shipping & factory warranty on everything we sell. Find The Right Part Right Now at Midwest.

Gallery

Attributes

Brand name, Manufacturer name, Manufacturer, Brand, Label, Publisher, StudioVeris
ConditionNEW
Extra Product NamePWLN04S Veris Industries 3wire DiffPressureXdcr 0-100# | Midwest Appliance Parts
keywords3 WIRE TRANSUCER
moq, multiple, tierMinQty1, NumberOfItems, Number_of_items1
MPN, Keyword, Model, ModelNumber, Model_number, PartNumber, Part_numberPWLN04S
qtyInStockCurrent Unavailable - No ETA Available
SKUPWLN04S-VE-P
snippetAuthentic OEM part PWLN04S by Veris. We provide free shipping & factory warranty on everything we sell. Find The Right Part Right Now at Midwest.
tierPrice1643.43
ASIN, AsinB009XEP8QA
AdultProduct, Autographed, Memorabilia, TradeInEligibleFalse
Bullet_pointAPPLICATIONS Monitoring and controlling pump differential pressureChiller/boiler differential pressure dropCW/HW system differential pressureFeaturesThe jumper-selectable output switch for normal (4-20mAor reverse (20-4mAoperation provides application flexibility Rugged, die-cast enclosure provides NEMA 4 sealing Exceptional accuracy and stability Dual sensor design for improved overpressure toleranceJumper-controlled electronic surge dampening for high stabilityPushbutton zero calibration no trim pots to adjustLowest total installed costJumper-selectable port swap feature eliminates costly replumbing when the high and low ports are improperly plumbed Easy to use and designed to provide exceptional installation savings, the PWL Series is ideal for measuring pressure across pumps, filters, heat exchangers, compressors, and other non-corrosive wet media applications The LCD display allows easy visibility The PWL Series wet/wet pressure transducers incorporate microprocessor profiled sensors for exceptional accuracy and reliability
ClassificationId306827011
DisplayNameVoltage
Height375 56
ItemClassificationBASE_PRODUCT
ItemName, Item_name, TitleVeris,Pressure,Wet,Nema 4,LCD,NIST,0-100PSID, PWLN04S
Item_type_keywordvoltage-transducers
Item_weight1.9
Linkhttps://m.media-amazon.com/images/I/41jLnKF96eL._SL75_.jpg https://m.media-amazon.com/images/I/41jLnKF96eL.jpg
ProductGroup, WebsiteDisplayGroupNameBISS Basic
ProductType, ProductTypeNameELECTRONIC_COMPONENT
Product_descriptionInput Power 12 to 30VDC/24VAC nominalMaximum Current Draw DC: 125mA; AC: 280mAOutput 3-wire transmitter; user selectable 4-20mA (clipped and capped)/0-5V/0-10V Accuracy @ 25°C* Range A B C: ±1% F.S.; Range D: ±2% F.S.**Surge Damping Electronic; 5-second averagingTest Mode Overrides output to full-scale (20mA 5V 10V)Pressure Ranges (Selectable) 0-10/20/50/100psid (0-0.34/0.69/1.72/3.45 bar)Product Operating Environment -10° to 55°C (-140° to 130°F); 0 to 90%RH non-condensingLong Term Stability ±0.25% per yearZero Adjust Pushbutton auto-zero and digital input (2-pos terminal block)Status Indication Dual-color LED: Green = Normal Green Blinking = Low > High Red = Overrange Red Blinking = OverpressureHousing Material White powder-coated aluminumSensor:Media Compatibility Media compatible with 17-4 PH stainless steelProof Pressure Max. 2x F.S. rangeBurst Pressure Max. 5x F.S. rangeTemperature Compensated Range 0° to 50°C (32° to 122°F); TC Zero Media Temperature Limits -20° to 85°C (-4° to 185°F); 0 to 90% RH non-condensingFittings 1/8" NPT female thread 17-4 PH stainless Minimum input voltage for 4-20mA operation: 250 ohm loop (1-5V) = 12 VDC; 500 ohm loop (2-10V) = 15 VDC; Minimum input voltage for volt operation: 0-5VDC output = 12 VDC; 0-10VDC output = 15 VDC. *Accuracy combines linearity hysteresis and repeatability.**FS is defined as full span of selected range in bi-directional mode.
Product_site_launch_date2019-01-03T18:51:32.472Z
Style#N/A
URLhttps://m.media-amazon.com/images/I/41jLnKF96eL._SL75_.jpg
Unitpounds
Unitspixels pounds
VariantMAIN
WebsiteDisplayGroupbiss_basic_display_on_website
Weight1.9 1.90
Width500 75

Distributor offers

SellerSKUMOQIn stockMultiplePrices
midwestapplianceparts.comPWLN04S-VE-P1Current Unavailable - No ETA Available11 @ $643.43
midwestapplianceparts.comPWLN04S -VE-P11
industrialrefrigerationparts.comPWLN04S1Ships From Manufacturer11 @ $583.43
GalcoPWLN04S-VEIN111 @ $852.03
blackhawksupply.comPWLN04S1-211 @ $578.00
alliedcontrols.comPWLN04S1Factory Stock11 @ $538.70
associatedcontrolsinc.comPWLN04S1-211 @ $510.12

Related on Amazon

As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

Veris,Pressure,Wet,Nema 4,LCD,NIST,0-100PSID, PWLN04S
Brand: Veris
Input Power 12 to 30VDC/24VAC nominalMaximum Current Draw DC: 125mA; AC: 280mAOutput 3-wire transmitter; user selectable 4-20mA (clipped and capped)/0-5V/0-10V Accuracy @ 25°C* Range A B C: ±1% F.S.; Range D: ±2% F.S.**Surge Damping Electronic; 5-second averagingTest Mode Overrides output to full-scale (20mA 5V 10V)Pressure Ranges (Selectable) 0-10/20/50/100psid (0-0.34/0.69/1.72/3.45 bar)Product Operating Environment -10° to 55°C (-140° to 130°F); 0 to 90%RH non-condensingLong Term Stability ±0.25% per yearZero Adjust Pushbutton auto-zero and digital input (2-pos terminal block)Status Indication Dual-color LED: Green = Normal Green Blinking = Low > High Red = Overrange Red Blinking = OverpressureHousing Material White powder-coated aluminumSensor:Media Compatibility Media compatible with 17-4 PH stainless steelProof Pressure Max. 2x F.S. rangeBurst Pressure Max. 5x F.S. rangeTemperature Compensated Range 0° to 50°C (32° to 122°F); TC Zero Media Temperature Limits -20° to 85°C (-4° to 185°F); 0 to 90% RH non-condensingFittings 1/8" NPT female thread 17-4 PH stainless Minimum input voltage for 4-20mA operation: 250 ohm loop (1-5V) = 12 VDC; 500 ohm loop (2-10V) = 15 VDC; Minimum input voltage for volt operation: 0-5VDC output = 12 VDC; 0-10VDC output = 15 VDC. *Accuracy combines linearity hysteresis and repeatability.**FS is defined as full span of selected range in bi-directional mode.
Details
  • The PWL Series wet/wet pressure transducers incorporate microprocessor profiled sensors for exceptional accuracy and reliability
  • Easy to use and designed to provide exceptional installation savings, the PWL Series is ideal for measuring pressure across pumps, filters, heat exchangers, compressors, and other non-corrosive wet media applications
  • The LCD display allows easy visibility
  • APPLICATIONS Monitoring and controlling pump differential pressureChiller/boiler differential pressure dropCW/HW system differential pressureFeaturesThe jumper-selectable output switch for normal (4-20mAor reverse (20-4mAoperation provides application flexibility Rugged, die-cast enclosure provides NEMA 4 sealing Exceptional accuracy and stability
  • Dual sensor design for improved overpressure toleranceJumper-controlled electronic surge dampening for high stabilityPushbutton zero calibration no trim pots to adjustLowest total installed costJumper-selectable port swap feature eliminates costly replumbing when the high and low ports are improperly plumbed
Listing
Product groupBISS Basic
Product typeELECTRONIC_COMPONENT
ModelPWLN04S
Part numberPWLN04S
Items per pack1
LabelVeris
ManufacturerVeris
View on Amazon (paid link)