As an Amazon Associate, we earn from qualifying purchases.

VERIS . PWLN05S

Pressure Transducers

Gallery

Attributes

Brand name, Manufacturer nameVERIS
ManufacturerVERIS Veris
moq, multiple, Case, NumberOfItems, Number_of_items1
MPN, SKU, Part Number, Keyword, Model, ModelNumber, Model_number, PartNumber, Part_numberPWLN05S
qtyInStock0
Product GroupBISS
ASIN, AsinB009XEP838
AdultProduct, Autographed, Memorabilia, TradeInEligibleFalse
Brand, Label, Man, Publisher, StudioVeris
Bullet_pointAPPLICATIONS Monitoring and controlling pump differential pressureChiller/boiler differential pressure dropCW/HW system differential pressureFeaturesThe jumper-selectable output switch for normal (4-20mAor reverse (20-4mAoperation provides application flexibility Rugged, die-cast enclosure provides NEMA 4 sealing Exceptional accuracy and stability Dual sensor design for improved overpressure toleranceJumper-controlled electronic surge dampening for high stabilityPushbutton zero calibration no trim pots to adjustLowest total installed costJumper-selectable port swap feature eliminates costly replumbing when the high and low ports are improperly plumbed Easy to use and designed to provide exceptional installation savings, the PWL Series is ideal for measuring pressure across pumps, filters, heat exchangers, compressors, and other non-corrosive wet media applications The LCD display allows easy visibility The PWL Series wet/wet pressure transducers incorporate microprocessor profiled sensors for exceptional accuracy and reliability
CatIndustrial & Scientific
CatId16310091
CatTree16310091 16310161 256409011 5006545011
ClassificationId306935011
DisplayNamePressure Probes & Sensors
Height375 56
IsBrandQueryTrue
ItemClassificationBASE_PRODUCT
ItemName, Item_nameVeris,Pressure,Wet,Nema 4,LCD,0-250PSID,NIST, PWLN05S
Item_type_keywordelectronic-pressure-sensors
Item_weight1.9
Linkhttps://m.media-amazon.com/images/I/41jLnKF96eL._SL75_.jpg https://m.media-amazon.com/images/I/41jLnKF96eL.jpg
ProductCategoryId306935011 biss_display_on_website
ProductGroupBISS BISS Basic
ProductType, ProductTypeNameELECTRONIC_COMPONENT
Product_descriptionInput Power 12 to 30VDC/24VAC nominalMaximum Current Draw DC: 125mA; AC: 280mAOutput 3-wire transmitter; user selectable 4-20mA (clipped and capped)/0-5V/0-10V Accuracy @ 25°C* Range A B C: ±1% F.S.; Range D: ±2% F.S.**Surge Damping Electronic; 5-second averagingTest Mode Overrides output to full-scale (20mA 5V 10V)Pressure Ranges (Selectable) 0-10/20/50/100psid (0-0.34/0.69/1.72/3.45 bar)Product Operating Environment -10° to 55°C (-140° to 130°F); 0 to 90%RH non-condensingLong Term Stability ±0.25% per yearZero Adjust Pushbutton auto-zero and digital input (2-pos terminal block)Status Indication Dual-color LED: Green = Normal Green Blinking = Low > High Red = Overrange Red Blinking = OverpressureHousing Material White powder-coated aluminumSensor:Media Compatibility Media compatible with 17-4 PH stainless steelProof Pressure Max. 2x F.S. rangeBurst Pressure Max. 5x F.S. rangeTemperature Compensated Range 0° to 50°C (32° to 122°F); TC Zero Media Temperature Limits -20° to 85°C (-4° to 185°F); 0 to 90% RH non-condensingFittings 1/8" NPT female thread 17-4 PH stainless Minimum input voltage for 4-20mA operation: 250 ohm loop (1-5V) = 12 VDC; 500 ohm loop (2-10V) = 15 VDC; Minimum input voltage for volt operation: 0-5VDC output = 12 VDC; 0-10VDC output = 15 VDC. *Accuracy combines linearity hysteresis and repeatability.**FS is defined as full span of selected range in bi-directional mode.
Product_site_launch_date2019-01-03T18:51:32.784Z
Rank1122635 439 477 501 762667 801176 829335 890
SkuOMNIA 440/00BF.PA1 UNIRISE USA, LLC PC6-02F-ORG WEIAND 6904WIN
Style#N/A
TitleVeris PWLN05S : Wet Media Differential Pressure Transducer Veris,Pressure,Wet,Nema 4,LCD,0-250PSID,NIST, PWLN05S
URLhttp://ecx.images-amazon.com/images/I/41jLnKF96eL._SL75_.jpg https://m.media-amazon.com/images/I/41jLnKF96eL._SL75_.jpg
Unitpounds
Unitspixels pounds
VariantMAIN
WebsiteDisplayGroupbiss_basic_display_on_website
WebsiteDisplayGroupNameBISS Basic
Weight1.9 1.90
Width500 75

Distributor offers

SellerSKUMOQIn stockMultiplePrices
RadwellPWLN05S11
GalcoPWLN05S111 @ $774.54
midwestapplianceparts.comPWLN05S-VE-P11
ptacsolutions.comPWLN05S111 @ $794.49
GalcoPWLN05S-VEIN111 @ $0.00
blackhawksupply.comPWLN05S1-211 @ $578.00
alliedcontrols.comPWLN05S1Factory Stock11 @ $538.70
associatedcontrolsinc.comPWLN05S1-211 @ $510.12
industrialrefrigerationparts.comPWLN05S1Ships From Manufacturer11 @ $583.43
industrialstores.comPWLN05S1Usually Ships 2 - 5 Days11 @ $672.47
KelePWLN05S111 @ $832.34

Related on Amazon

As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

Veris,Pressure,Wet,Nema 4,LCD,0-250PSID,NIST, PWLN05S
Brand: Veris
Input Power 12 to 30VDC/24VAC nominalMaximum Current Draw DC: 125mA; AC: 280mAOutput 3-wire transmitter; user selectable 4-20mA (clipped and capped)/0-5V/0-10V Accuracy @ 25°C* Range A B C: ±1% F.S.; Range D: ±2% F.S.**Surge Damping Electronic; 5-second averagingTest Mode Overrides output to full-scale (20mA 5V 10V)Pressure Ranges (Selectable) 0-10/20/50/100psid (0-0.34/0.69/1.72/3.45 bar)Product Operating Environment -10° to 55°C (-140° to 130°F); 0 to 90%RH non-condensingLong Term Stability ±0.25% per yearZero Adjust Pushbutton auto-zero and digital input (2-pos terminal block)Status Indication Dual-color LED: Green = Normal Green Blinking = Low > High Red = Overrange Red Blinking = OverpressureHousing Material White powder-coated aluminumSensor:Media Compatibility Media compatible with 17-4 PH stainless steelProof Pressure Max. 2x F.S. rangeBurst Pressure Max. 5x F.S. rangeTemperature Compensated Range 0° to 50°C (32° to 122°F); TC Zero Media Temperature Limits -20° to 85°C (-4° to 185°F); 0 to 90% RH non-condensingFittings 1/8" NPT female thread 17-4 PH stainless Minimum input voltage for 4-20mA operation: 250 ohm loop (1-5V) = 12 VDC; 500 ohm loop (2-10V) = 15 VDC; Minimum input voltage for volt operation: 0-5VDC output = 12 VDC; 0-10VDC output = 15 VDC. *Accuracy combines linearity hysteresis and repeatability.**FS is defined as full span of selected range in bi-directional mode.
Details
  • The PWL Series wet/wet pressure transducers incorporate microprocessor profiled sensors for exceptional accuracy and reliability
  • Easy to use and designed to provide exceptional installation savings, the PWL Series is ideal for measuring pressure across pumps, filters, heat exchangers, compressors, and other non-corrosive wet media applications
  • The LCD display allows easy visibility
  • APPLICATIONS Monitoring and controlling pump differential pressureChiller/boiler differential pressure dropCW/HW system differential pressureFeaturesThe jumper-selectable output switch for normal (4-20mAor reverse (20-4mAoperation provides application flexibility Rugged, die-cast enclosure provides NEMA 4 sealing Exceptional accuracy and stability
  • Dual sensor design for improved overpressure toleranceJumper-controlled electronic surge dampening for high stabilityPushbutton zero calibration no trim pots to adjustLowest total installed costJumper-selectable port swap feature eliminates costly replumbing when the high and low ports are improperly plumbed
Listing
Product groupBISS Basic
Product typeELECTRONIC_COMPONENT
ModelPWLN05S
Part numberPWLN05S
Items per pack1
LabelVeris
ManufacturerVeris
Catalog
CategoryIndustrial & Scientific
MPNPWLN05S
Product groupBISS
Product typeELECTRONIC_COMPONENT
ManufacturerVeris
View on Amazon (paid link)