ICM Controls ICM325HNC Head Pressure Control - For A/C & Heat Pumps - 120-480 VAC
The ICM325HNC Head Pressure Control from ICM Controls is a device that helps prevent evaporator freeze-up by varying the amount of air through the condenser. It has a control voltage range of 18 to 30 volts and can function in low ambient conditions. The unit requires a separate 24 VAC source and has a built-in status indicator with green and yellow lights. It also features adjustable hard start timing and motor cutout speed pressure.
Buy ICM Controls ICM325HNC Today. Check the ICM Controls Head Pressure Control - For A/C & Heat Pumps - 120-480 VAC ratings before checking out.
Gallery
Attributes
| Brand name, Manufacturer name, Brand, Label, Man, Publisher, Studio | ICM Controls |
|---|---|
| Manufacturer | ICM Controls ICM |
| Extra Product Name | ICM Controls ICM325HNC Head Pressure Control - For A/C & Heat Pumps - 120-480 VAC |
| keywords | ICM325HNC,ICM Controls ICM325HNC,ICM Controls ICM325HNC Central Air Conditioners,ICM Controls Head Pressure Control - For A/C & Heat Pumps - 120-480 VAC,800442011455 |
| moq, multiple, tierMinQty1, Case, Item_package_quantity, PackageQuantity | 1 |
| MPN, SKU, Part Number, ModelNumber, Model_number, Mpns, PartNumber, Part_number, StrippedMpns | ICM325HNC |
| qtyInStock | -2 |
| qtySource | FieldMap |
| snippet | Buy ICM Controls ICM325HNC Today. Check the ICM Controls Head Pressure Control - For A/C & Heat Pumps - 120-480 VAC ratings before checking out. |
| tierPrice1 | 130.00 |
| UPC, EAN, EANList, UPCList | 94706859581 |
| Product Group, ProductGroup | Home Improvement |
| AdultProduct, Autographed, Batteries_included, Batteries_required, Memorabilia, TradeInEligible | False |
| Asin | B007EWXK36 B07HLXBPPF |
| Binding | Misc. |
| Bullet_point | Price For: Each Controls: Head Pressure By Varying the Amount of Air Through the Condenser to Help Prevent Evaporator Freeze Up Item: Head Pressure Control Ambient Temp. Range (C): -40 to 75 Control Volts: 18 to 30 Function: High Temperature Bypass, Heat Pump Override and Adjustable Hard Start Timming and Motor Cutout Speed Pressure: Low, Cutoff and Liquid Slugging in Low Ambient Condition Status Indicator: Green and Yellow Light, Full or Modulated Motor Voltage at a Glance Requires: Separate 24 VAC Source Hard Start Timing (Sec.): 0.1 to 5.0 Triac Output Amps: 0.1 to 10.0 Input Volts AC @ 60/50 Hz: 120 to 480 Country of Origin (subject to change): United States |
| Cat | Industrial & Scientific |
| CatId | 16310091 |
| CatTree | 16310091 16310161 306506011 306528011 |
| ClassificationId | 306529011 |
| DisplayName | Controllers |
| Height | 2.0 4.7 482 72 |
| Identifier | 0696334316674 696334316674 |
| IdentifierType | EAN UPC |
| ItemClassification | BASE_PRODUCT |
| ItemName, Item_name | ICM Head Pressure Control |
| Item_type_keyword | electronic-controllers |
| Item_weight, Weight | 0.08 |
| Keyword | G3442975 |
| Length | 2.0 7.8 |
| Link | https://m.media-amazon.com/images/I/51lQR-uj8EL._SL75_.jpg https://m.media-amazon.com/images/I/51lQR-uj8EL.jpg |
| Material | Other |
| ProductType | HOME_LIGHTING_ACCESSORY |
| ProductTypeName | TOOLS |
| Product_description | ' Head Pressure Control, Hard Start Timing 0.1-5.0 Seconds, Triac Output Current 0.1-10.0 Amps, Built In 24 Volt Transformer No, With Heat Pump Bypass, Output Voltage 120-480 VAC ' |
| Product_site_launch_date | 2012-01-26T17:33:05.088Z |
| Title | Head Pressure Control |
| Type | ean upc |
| Unit | inches pounds |
| Variant | MAIN |
| WebsiteDisplayGroup | biss_basic_display_on_website |
| WebsiteDisplayGroupName | BISS Basic |
| Width | 2.0 500 6.0 75 |
Distributor offers
| Seller | SKU | MOQ | In stock | Multiple | Prices |
|---|---|---|---|---|---|
| ICM325HNC | 1 | -2 | 1 | 1 @ $130.00 | |
![]() Voomi Supply | ICM325HNC | 1 | -2 | 1 | 1 @ $125.09 |
| sustainablesupply.com | C1137963 | 1 | -2 | 1 | 1 @ $114.65 |
| ICM325HNC | 1 | 1 |
Related on Amazon
As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Head Pressure Control
Brand: ICM Controls
Catalog
| Category | Industrial & Scientific |
|---|---|
| MPN | ICM325HNC |
| UPC | 94706859581 |
| EAN | 94706859581 |
| Product group | Home Improvement |
| Product type | TOOLS |
| Manufacturer | ICM Controls |
ICM Head Pressure Control
Brand: ICM Controls
' Head Pressure Control, Hard Start Timing 0.1-5.0 Seconds, Triac Output Current 0.1-10.0 Amps, Built In 24 Volt Transformer No, With Heat Pump Bypass, Output Voltage 120-480 VAC '
Details
- Price For: Each Controls: Head Pressure By Varying the Amount of Air Through the Condenser to Help Prevent Evaporator Freeze Up Item: Head Pressure Control Ambient Temp. Range (C): -40 to 75 Control Volts: 18 to 30 Function: High Temperature Bypass, Heat Pump Override and Adjustable Hard Start Timming and Motor Cutout Speed Pressure: Low, Cutoff and Liquid Slugging in Low Ambient Condition
- Status Indicator: Green and Yellow Light, Full or Modulated Motor Voltage at a Glance Requires: Separate 24 VAC Source Hard Start Timing (Sec.): 0.1 to 5.0 Triac Output Amps: 0.1 to 10.0 Input Volts AC @ 60/50 Hz: 120 to 480 Country of Origin (subject to change): United States