As an Amazon Associate, we earn from qualifying purchases.

modular discovery packs, Zelio Logic SR2 SR3, smart relay discovery pack, 26 IO, 24V DC | Mayer Electric

Shop SCHNEIDER ELECTRIC at Mayer. Modular smart relay Zelio Logic - ?discovery? pack - 26 I O - 24 V DC

Gallery

Attributes

Brand name, Manufacturer name, ManufacturerMayer Electric Supply
Extra Product Namemodular discovery packs, Zelio Logic SR2 SR3, smart relay discovery pack, 26 IO, 24V DC | Mayer Electric
UPC3389110550047
Weight0.85
WeightUnitkg
Weight_AttribNet Weight
jsonUrlData/Product/SCHNEIDER-ELECTRIC-Modular-smart-relay-Zelio-Logic-discovery-pack-26-I-O-24-V-DC-785901571919
jsonUrlData2000040a9-5c96-4e81-811e-abd200632ad2
keywordsSQUARE D, Mayer SQUARE D, 785901571919, SR3PACK2BD
moq, multiple, tierMinQty11
MPNSR3PACK2BD
qtyInStock0
SKUSQDSR3PACK2BD
snippetShop SCHNEIDER ELECTRIC at Mayer. Modular smart relay Zelio Logic - ?discovery? pack - 26 I O - 24 V DC
tierPrice1584.61
Relative Humidity95-95 % without condensation or dripping water
Disturbance Radiated/Conductedclass B EN 55022-11 group 1
Product CertificationsGOST || GL || UL || CSA || C-tick
Environmental CharacteristicEMC directive EN/IEC 61000-6-2 || EMC directive EN/IEC 61000-6-3 || EMC directive EN/IEC 61000-6-4 || EMC directive EN/IEC 61131-2 zone B || low voltage directive EN/IEC 61131-2
Ambient Air Temperature For Operation-20-40 ?C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 || -20-55 ?C IEC 60068-2-1 and IEC 60068-2-2
Pollution Degree2 EN/IEC 61131-2
Maximum Altitude Transport3048 m
Immunity To Microbreaks1 ms
Ambient Air Temperature For Storage-40-70 ?C
Ip Degree Of ProtectionIP20 IEC 60529 terminal block) || IP40 IEC 60529 front panel)
Operating Altitude6561.68 ft (2000 m)
Warranty18 months
Environmental DisclosureENVPEP060406EN
Sustainable Offer StatusGreen Premium product
Circularity ProfileENVEOLI0604006EN
Reach RegulationReference contains Substances of Very High Concern above the threshold
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Mercury Free, Pvc Free, Rohs Exemption InformationYes
California Proposition 65 : WARNING: This product can expose you to chemicals includingLead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs RegulationX
Response Time10 ms from state 0 to state 1)relay output || 5 ms from state 1 to state 0)relay output
Checksprogram memory on each power up
Backup Time10 years 25 ?C
Voltage State 1 Guaranteed>= 15 V I1...IA and IH...IR discrete input circuit || >= 15 V IB...IG used as discrete input circuit
Net Weight0.85 kg
Discrete Input Typeresistive
Current State 1 Guaranteed>= 1.2 mA IB...IG used as discrete input circuit) || >= 2.2 mA I1...IA and IH...IR discrete input circuit)
Clock Drift12 min/year 0-55 ?C || 6 s/month 25-25 ?C
Maximum Permissible Voltage30 V analogue input circuit
Tightening Torque0.5 N.m
Switching Capacity In Ma>= 10 mA 12 V relay output)
Input Compatibility3-wire proximity sensors PNP discrete input
Analogue Input Typecommon mode
Discrete Input Current4 mA
Power Dissipation In W10 W with extensions || 6 W without extension
Conversion Timesmart relay cycle time analogue input circuit
Analogue Input Resolution8 bits
Cycle Time6-90 ms
Counting Frequency1 kHz discrete input
Contacts Type And CompositionNO relay output
[Us] Rated Supply Voltage24 V
Overvoltage CategoryIII EN/IEC 60664-1
Supply Voltage Limits19.2-30 V
Analogue Input Range0...10 V || 0...24 V
Temperature Probe TypeNTC 10k 25 ?C || NTC 1000k 25 ?C || KTY81 210/220/221/222/250 || Pt 500
[Uimp] Rated Impulse Withstand Voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
Reverse Polarity Protection, Clock, Local Displaywith
Conversion Error+/- 5 % 25 ?C analogue input circuit || +/- 6.2 % 55 ?C analogue input circuit
Repeat Accuracy+/- 2 % 55 ?C analogue input circuit
Analogue Input Number6
Maximum Supply Current190 mA without extension) || 300 mA with extensions)
Operating Distance10 m between stations, with screened cable (sensor not isolated) analogue input circuit
Mechanical Durability10000000 cycles relay output
Output Voltage Limits24...250 V AC relay output) || 5...30 V DC relay output)
Lsb Value39 mV analogue input circuit
Output Thermal Current5 A for 2 outputs relay output || 8 A for 8 outputs relay output
Discrete Input Voltage24 V DC
Number Or Control Scheme Lines120-120 ladder || 0-200 FBD
Input Impedance12 kOhm IB...IG used as analogue input circuit || 12 kOhm IB...IG used as discrete input circuit || 7.4 kOhm I1...IA and IH...IR discrete input circuit
Operating Rate In Hz0.1 Hz at Ie)relay output || 10 Hz no load)relay output
Kit Compositioncable PC SR2USB01 for connection to PC || SR3B261BD
Input/Output Number26
Range Of ProductZelio Logic
Discrete Input Number16 EN/IEC 61131-2 type 1
Number Of Outputs10 relay
Product Or Component Typemodular discovery packs

Distributor offers

SellerSKUMOQIn stockMultiplePrices
mayerelectric.comSQDSR3PACK2BD111 @ $584.61