MACURCO . TX-6-ND
Gas Detector NO2 0 to 20 ppm | 36CF96 | Worldwide Delivery | +44 203 287 5224 | [email protected]
Gallery
Attributes
| Brand name, Manufacturer name, Manufacturer, Label, Man, Publisher, Studio | MACURCO |
|---|---|
| Part Number, MPN, Model, ModelNumber, Model_number, Mpns, PartNumber, Part_number | TX-6-ND |
| Product Group | BISS |
| ASIN, Asin | B00DE23O0E |
| AdultProduct, Autographed, Batteries_required, Memorabilia, TradeInEligible | False |
| Alarm | Vibration |
| Amount | 703.12 |
| Aspect | proper_shipping_name |
| Binding | Misc. |
| Brand | Macurco |
| Bullet_point | Country of Origin (subject to change) : United States Operating Temp. Range : 0 Degrees to 125 Degrees F (-18 Degrees to 52 Degrees C) Includes : Manual Power Required : 12 to 24VAC or 12 to 32VDC Height : 4-1/2" Alarm Type : Audible and Visual Gas Type : NO2 Sensor Range : 0 to 20 ppm Depth : 2-1/8" Color : Gray Display : LED Connection : Plugs/Terminals Width : 4" Number of Channels : 2 Item : Gas Detector, Controller, Transducer Status Indicator : Yes Price For: Each Resolution : 1 ppm Features : Powered by Low Voltage, ETL Listed, Supervised System Design, Detector Problem Will Cause the Fan and Alarm Relay to Activate, 2-3 Year Sensor Life, Replaceable Sensor, End of Life Indication, Digital Readout Display, Internal Buzzer, Onboard Relays (2), 4-20mA Transduced current loop Standards : ETL Listed to UL 61010-1, CAN/CSA C22.2 No. 61010-1 |
| Case, Item_package_quantity, NumberOfItems, Number_of_items, PackageQuantity | 1 |
| Cat | Industrial & Scientific |
| CatId | 16310091 |
| CatTree | 16310091 16310161 |
| ClassificationId | 7491102011 |
| Color | Gray |
| CurrencyCode | USD |
| DisplayName | Gas Detectors & Alarms |
| Feature | Price For: Each Resolution : 1 ppm Features : Powered by Low Voltage, ETL Listed, Supervised System Design, Detector Problem Will Cause the Fan and Alarm Relay to Activate, 2-3 Year Sensor Life, Replaceable Sensor, End of Life Indication, Digital Readout Display, Internal Buzzer, Onboard Relays (2), 4-20mA Transduced current loop Standards : ETL Listed to UL 61010-1, CAN/CSA C22.2 No. 61010-1 |
| Hazmat | auto-grounding |
| Height | 18 18.0 18.00 4.5 500 75 |
| Identifier | 7739178743657 |
| IdentifierType | EAN |
| IsBrandQuery | True |
| ItemClassification | BASE_PRODUCT |
| ItemName, Item_name | Gas Detector, NO2, 0 to 20 ppm |
| Item_package_weight, Item_weight | 4.58 |
| Item_type_keyword | explosive-gas-detectors |
| Keyword | 61010-ND |
| Length | 2.125 21 21.0 21.00 |
| Link | https://m.media-amazon.com/images/I/4198RKIypeL._SL75_.jpg https://m.media-amazon.com/images/I/4198RKIypeL.jpg https://www.amazon.com/gp/bestsellers/hi https://www.amazon.com/gp/bestsellers/hi/7491102011 |
| Operating_humidity | 95 percent |
| Power_source_type | Battery Powered |
| ProductCategoryId | 7491102011 home_improvement_display_on_website |
| ProductGroup | BISS Home Improvement |
| ProductType | GAS_SMOKE_FIRE_ALARM |
| ProductTypeName | GAS_SMOKE_FIRE_ALARM MECHANICAL_COMPONENTS SAFETY_SUPPLY |
| Product_description | 'Gas Detector, Controller, Transducer, Gas Type NO2, Number of Channels 2, Sensor Range 5000 sq. ft., Alarm Type Internal Buzzer, Display LED, Status Indicator Yes, Features Supervised System Design, Detector Problem Will Cause The Fan and Alarm Relay to Activate, For Use With Stand Alone or with DVP-120 Control Panel, Power Required 12-24VAC or 12-32 VDC, Height 4.50, Width 4.0, Depth 2.18, Color Gray, Operating Temp. Range 0 Degrees to 125 Degrees F ( -18 Degrees to 52 Degrees C )' |
| Product_site_launch_date | 2017-08-14T10:39:57.529Z |
| Rank | 1680794 1688238 2008539 278 392 565849 600 661 769 865822 |
| Sku | MACURCO 70-2900-0605-4 MACURCO ND SENSOR MACURCO TX-6-ND |
| StrippedMpns | TX6ND |
| Style | Industrial |
| Supplier_declared_dg_hz_regulation | unknown |
| Title | Gas Detector, NO2, 0 to 20 ppm Gas Detectors & Alarms Tools & Home Improvement |
| Type | Each ean |
| URL | http://ecx.images-amazon.com/images/I/51eoIgbLWmL._SL75_.jpg https://m.media-amazon.com/images/I/51eoIgbLWmL._SL75_.jpg |
| Unit | degrees_celsius inches pounds |
| Unit_count | 1.0 |
| Units | inches pixels pounds |
| Upper_temperature_rating | 52.0 |
| Variant | MAIN |
| WebsiteDisplayGroup | home_improvement_display_on_website |
| WebsiteDisplayGroupName | Home Improvement |
| Weight | 0.000625 0.01 4.58 |
| Width | 18 18.0 18.00 4 500 75 |
Distributor offers
| Seller | SKU | MOQ | In stock | Multiple | Prices |
|---|---|---|---|---|---|
| 36CF96 | 1 | 15 | 1 | 1 @ $810.00 | |
| Zoro | G9476591 | 1 | 1 | ||
| AH6HQZ | 1 | 1 | 1 @ $977.58 | ||
![]() AmazonTP | B00DE23O0E | 1 | 1 | 1 @ $480.83 | |
| Amazon | B00DE23O0E | 1 | 1 | ||
![]() surveillance-video.com | TX-6-ND | 1 | -2 | 1 | 1 @ $603.00 |
Related on Amazon
As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Gas Detector, NO2, 0 to 20 ppm
Brand: Macurco
'Gas Detector, Controller, Transducer, Gas Type NO2, Number of Channels 2, Sensor Range 5000 sq. ft., Alarm Type Internal Buzzer, Display LED, Status Indicator Yes, Features Supervised System Design, Detector Problem Will Cause The Fan and Alarm Relay to Activate, For Use With Stand Alone or with DVP-120 Control Panel, Power Required 12-24VAC or 12-32 VDC, Height 4.50, Width 4.0, Depth 2.18, Color Gray, Operating Temp. Range 0 Degrees to 125 Degrees F ( -18 Degrees to 52 Degrees C )'
Details
- Price For: Each Resolution : 1 ppm Features : Powered by Low Voltage, ETL Listed, Supervised System Design, Detector Problem Will Cause the Fan and Alarm Relay to Activate, 2-3 Year Sensor Life, Replaceable Sensor, End of Life Indication, Digital Readout Display, Internal Buzzer, Onboard Relays (2), 4-20mA Transduced current loop Standards : ETL Listed to UL 61010-1, CAN/CSA C22.2 No. 61010-1
- Operating Temp. Range : 0 Degrees to 125 Degrees F (-18 Degrees to 52 Degrees C) Includes : Manual Power Required : 12 to 24VAC or 12 to 32VDC Height : 4-1/2" Alarm Type : Audible and Visual Gas Type : NO2 Sensor Range : 0 to 20 ppm Depth : 2-1/8" Color : Gray Display : LED Connection : Plugs/Terminals Width : 4" Number of Channels : 2 Item : Gas Detector, Controller, Transducer Status Indicator : Yes
- Country of Origin (subject to change) : United States
Listing
| Product group | BISS |
|---|---|
| Product type | MECHANICAL_COMPONENTS |
| Part number | TX-6-ND |
| Items per pack | 1 |
| Label | MACURCO |
| Manufacturer | MACURCO |
Catalog
| Feature | Price For: Each Resolution : 1 ppm Features : Powered by Low Voltage, ETL Listed, Supervised System Design, Detector Problem Will Cause the Fan and Alarm Relay to Activate, 2-3 Year Sensor Life, Replaceable Sensor, End of Life Indication, Digital Readout Display, Internal Buzzer, Onboard Relays (2), 4-20mA Transduced current loop Standards : ETL Listed to UL 61010-1, CAN/CSA C22.2 No. 61010-1 |
|---|---|
| Category | Industrial & Scientific |
| MPN | TX-6-ND |
| Product group | BISS |
| Product type | MECHANICAL_COMPONENTS |
| Manufacturer | MACURCO |