As an Amazon Associate, we earn from qualifying purchases.

Buy Gossen M503N, Mavolux 5032B USB Illuminance Meter - Prime Buy

Gallery

Attributes

Brand name, Manufacturer name, Brand, Label, Man, Publisher, StudioGossen
ManufacturerGossen DRANETZ TECHNOLOGIES INC
ConditionNEWCONDITION
Extra Product NameBuy Gossen M503N, Mavolux 5032B USB Illuminance Meter - Prime Buy
moq, multiple, tierMinQty1, Case, Item_package_quantity, NumberOfItems, PackageQuantity1
MPN, SKU, Part Number, ModelNumber, Model_number, Mpns, PartNumber, Part_number, StrippedMpnsM503N
qtyInStock4-6 Weeks Factory Lead Time
tierPrice11267.00
Product GroupBISS
Measuring Ranges5
Measuring Range SelectionAutomatic/manual
Measuring Rate2 per second
Measuring MethodDistance measurement, Distance measurement, and Contact measurement
Measuring SensorSilicon photodiode with V (Λ) filter
Probe with Tripod ThreadYes
Measurement Cable1.5 m, plug-in
Measured Value Memory100 measured values
Error Limit - Overall Error, Typical≤ 8 %
Accuracy± 3 % of reading ± 1 digit
ASIN, AsinB012XBE4ZA
AdultProduct, Autographed, Batteries_included, Batteries_required, Memorabilia, TradeInEligibleFalse
Amount1159.00
BindingMisc.
Bullet_pointBroad measuring range - High initial sensitivity and a resolution of 0.01 lx or 0.001 fc for the MAVOLUX 5032 B USB, right on up to large illuminance values of 199,900 lx or 19,990 fc. Cosine correction - The luminosity of a flat measuring surface is proportional to the cosine of the incident angle of light. This relationship is taken into consideration by the sensor during evaluation. MAVOLUX 5032 B USB Maximum precision - Classified measurement of illuminance in lx or fc in accordance with class B or class C per DIN 5032-7, appendix B of IEC 13032-1 and CIE 69. V(λ) adaptation - The spectral sensitivity of the silicon photodiode is color corrected and corresponds to the spectral brightness sensitivity of the human eye V(λ) The quality of this adaptation represents a significant difference between the class B and class C variants.
CatIndustrial & Scientific
CatId16310091
CatTree16310091 16310161 317970011 317980011
ClassificationId3109913011
Connectivity_technologyUSB Cable
Connector_genderMale-to-Male
Connector_type, Headphones_jackUsb
Currency, CurrencyCodeUSD
DisplayNameLight Meters
FeatureMAVOLUX 5032 B USB
Height375 4.0 4.30 56 75 768
ItemClassificationBASE_PRODUCT
ItemName, Item_nameGossen M503N MAVOLUX 5032 B USB
Item_package_weight200.0
Item_shapeRound
Item_type_keywordphotographic-light-meters
Item_weight5.61
Keyword5032B
Length15.0 15.20
Linkhttps://m.media-amazon.com/images/I/21B3b9+x8PL._SL75_.jpg https://m.media-amazon.com/images/I/21B3b9+x8PL.jpg https://m.media-amazon.com/images/I/41Fhh9EcnzL.jpg https://www.amazon.com/gp/bestsellers/electronics/3109913011
List_price1333.57
ProductCategoryId19568045011 home_improvement_display_on_website
ProductGroupBISS Home Improvement
ProductTypeELECTRONIC_CABLE
ProductTypeNameELECTRONIC_COMPONENT TOOLS
Product_descriptionGossen M503N MAVOLUX 5032 B USBThis high precision luxmeter is available in class B and class C versions in accordance with DIN 5032-7, appendix B of IEC 13032-1 and CIE 69. Both variants are equipped with V(?) adaptation as well as cosine correction, and reliably measure the illuminance of daylight and artificial sources of light. Even in the case of very bright sunlight or light from headlights, no accessories are required.Due to its outstanding accuracy in accordance with class B, the MAVOLUX 5032 B USB is used primarily for certification and inspection applications. An additional measuring range with high initial sensitivity of 0.01 lx makes it possible to measure extremely small light intensities. This even permits reliable measurement of emergency lighting. After pressing the HOLD key, the measured value is saved to memory and display illumination included with this version is activated, making it possible to read the display in dark environments. Adaptation to the spectral brightness sensitivity of the human eye V(?) is highly precise with minimal deviation of just f1'With accuracy according to class C, the industrial luxmeter Mavolux 5032 C USB is primarily used for general applications. The smallest of four measuring ranges begins with an initial sensitivity of 0.1 lx. V(?) adaptation deviation, which amounts to f1'Both variants can be used as unclassified luminance meters with the help of an optional luminance attachment with an acceptance angle of 15degrees-.Luminance is measured in candelas per square meter (cd/m) or foot-lamberts (fL), and defines the perceived brightness of a back-lighted or reflecting surface.At GOSSEN, great emphasis is placed upon reliability by means of calibration. For purposes of documented evidence, a factory calibration certificate or a DAkkS calibration certificate can be ordered along with either variant. Depending on how the meter is used, we recommend a calibration interval of
Product_site_launch_date2015-07-01T14:34:19.072Z
Rank12532 357 4131156
Specification_metIEC
Supplier_declared_dg_hz_regulationnot_applicable
TitleGossen M503N MAVOLUX 5032 B USB Photographic Light Meters
TypeCount USB
URLhttp://ecx.images-amazon.com/images/I/31ZAJwWooML._SL75_.jpg
Unitgrams inches pounds
Unit_count1.0
Unitsinches pixels pounds
VariantMAIN
WebsiteDisplayGrouphome_improvement_display_on_website
WebsiteDisplayGroupNameHome Improvement
Weight0.440924524 5.61 6.00
Width1024 12.50 13.0 500 54 75

Distributor offers

SellerSKUMOQIn stockMultiplePrices
primebuy.comM503N14-6 Weeks Factory Lead Time11 @ $1267.00

Related on Amazon

As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

Gossen M503N MAVOLUX 5032 B USB
Brand: Gossen
Gossen M503N MAVOLUX 5032 B USBThis high precision luxmeter is available in class B and class C versions in accordance with DIN 5032-7, appendix B of IEC 13032-1 and CIE 69. Both variants are equipped with V(?) adaptation as well as cosine correction, and reliably measure the illuminance of daylight and artificial sources of light. Even in the case of very bright sunlight or light from headlights, no accessories are required.Due to its outstanding accuracy in accordance with class B, the MAVOLUX 5032 B USB is used primarily for certification and inspection applications. An additional measuring range with high initial sensitivity of 0.01 lx makes it possible to measure extremely small light intensities. This even permits reliable measurement of emergency lighting. After pressing the HOLD key, the measured value is saved to memory and display illumination included with this version is activated, making it possible to read the display in dark environments. Adaptation to the spectral brightness sensitivity of the human eye V(?) is highly precise with minimal deviation of just f1'With accuracy according to class C, the industrial luxmeter Mavolux 5032 C USB is primarily used for general applications. The smallest of four measuring ranges begins with an initial sensitivity of 0.1 lx. V(?) adaptation deviation, which amounts to f1'Both variants can be used as unclassified luminance meters with the help of an optional luminance attachment with an acceptance angle of 15degrees-.Luminance is measured in candelas per square meter (cd/m) or foot-lamberts (fL), and defines the perceived brightness of a back-lighted or reflecting surface.At GOSSEN, great emphasis is placed upon reliability by means of calibration. For purposes of documented evidence, a factory calibration certificate or a DAkkS calibration certificate can be ordered along with either variant. Depending on how the meter is used, we recommend a calibration interval of
Details
  • MAVOLUX 5032 B USB
  • Maximum precision - Classified measurement of illuminance in lx or fc in accordance with class B or class C per DIN 5032-7, appendix B of IEC 13032-1 and CIE 69.
  • Broad measuring range - High initial sensitivity and a resolution of 0.01 lx or 0.001 fc for the MAVOLUX 5032 B USB, right on up to large illuminance values of 199,900 lx or 19,990 fc.
  • V(λ) adaptation - The spectral sensitivity of the silicon photodiode is color corrected and corresponds to the spectral brightness sensitivity of the human eye V(λ) The quality of this adaptation represents a significant difference between the class B and class C variants.
  • Cosine correction - The luminosity of a flat measuring surface is proportional to the cosine of the incident angle of light. This relationship is taken into consideration by the sensor during evaluation.
Listing
BindingMisc.
Product groupHome Improvement
Product typeTOOLS
Part numberM503N
LabelGossen
ManufacturerGossen
Catalog
FeatureMAVOLUX 5032 B USB
CategoryIndustrial & Scientific
MPNM503N
Product groupBISS
Product typeELECTRONIC_COMPONENT
ManufacturerGossen
View on Amazon (paid link)